Workpackage: Communication/Logical Protocol
This page contains information about the Technical Workpackage Communication/Logical Protocol
Leader: Bernhard Tittelbach
Telemetry Protocol Specification revision 249
Protocol Definition for TTX Beacon to Ground Stations ===================================================== Introduction ------------ - using CW - transceiver should send a beacon about every 60s - transceiver sends acknowledge frame if requested - parity Signs (Char Table) ------------------ !"$&'()+ ,-./0123 456789:; <=>?@ABC DEFGHIJK LMNOPQRS TUVWXYZ Base32 Coded Signs ------------------ | 0 1 2 3 4 5 6 7 8 9 A B C D E F ------------------------------------- 00 | A B C D E F G H I J K L M N O P 10 | Q R S T U V W X Y Z 2 3 4 5 6 7 Beacon Frame: ------------- 'N' (1 Sign) .. Start Character (-.) CALLSIGN (4 Signs) .. the satellites call sign (i.e. OE0M) CNT (3 Signs) .. beacon counter (Base32) STATE (1 Sign) .. Base32 coded bitfield CMDQLEN (1 Sign) .. Number of commands in queue (Base32) ... tba CHECKSUM (1 Sign) .. Parity Sign Bitfields ~~~~~~~~~ STATE: LSB RX_STATE .. Payload Receiver State (0 = OFF, 1 = ON) ... tba MSB Acknowledge Frame ---------------- 'A' (1 Sign) .. Start Character (.-) CRXCODE (1 Sign) .. unscrambled command code from CRX CHECKSUM (1 Sign) .. Parity Sign
Additional information possibly to be included in telemetry beacon:
(depending on final duration of beacon versus contact window duration)
- Battery1-voltage
- Battery2-voltage
- Temperature for each sensor
- Solarcell-voltage separately for each of 8 solarcell panels
- Solcarcel-Volate (mean of all voltages)
- RX/TX receiver status
current EnergyTokenValue
possibly take some pages out of XW-1 Telemetry Format, especially number encoding.
Final equations of numerical values to be published on finalization of electrical systems design.